第二代的数据通信等领域用到的点负载功率模块与NC系列的产品相比,可以适应更宽的输入电压范围,这样它就可以与更广的母线电压匹配应用。第二代的数据通信等领域用到的点负载功率模块可以输出3安培到80安培的电流以满足不同的应用需求。
Part Number | Vin Range (VDC) | Vout Nominal (VDC) | lout (A) | Power (W) | Eff (%) | Package | LxWxH (mm) |
---|---|---|---|---|---|---|---|
D12S05020-1 | 4.5~13.2 | 0.59~5 | 20 | 100 | 93.4 | Through hole | 30.5x15.5x12 |
D12S300-1 | 4.5~13.8 | 0.6~5 | 60 | 300 | 94 | Through hole | 65.53x31.75x11.0 |
D12S400 | 10.8~13.2 | 0.8375~5 | 80 | 400 | 94 | Through hole | 61.0x31.8x12.3 |
NE12S0A0H03 | 3~13.8 | 0.59~5 | 3 | 15 | 92.5 | DIP | 9.4x15.5x7.9 |
NE12S0A0H06 | 3~13.8 | 0.59~5.1 | 6 | 30.6 | 94.5 | DIP | 10.4x16.5x11.5 |
NE12S0A0H10 | 3~13.8 | 0.59~5.1 | 10 | 51 | 94 | DIP | 10.4x16.5x11.5 |
NE12S0A0V03 | 3~13.8 | 0.59~5 | 3 | 15 | 92.5 | DIP | 9.4x15.5x7.9 |
NE12S0A0V06 | 3~13.8 | 0.59~5.1 | 6 | 30.6 | 94.5 | DIP | 10.4x16.5x11 |
NE12S0A0V10 | 3~13.8 | 0.59~5.1 | 10 | 51 | 94 | DIP | 10.4x16.5x11 |
Part Number | Vin Range (VDC) | Vout Nominal (VDC) | lout (A) | Power (W) | Eff (%) | Package | LxWxH (mm) |
---|---|---|---|---|---|---|---|
D12S05020-1 | 4.5~13.2 | 0.59~5 | 20 | 100 | 93.4 | Through hole | 30.5x15.5x12 |
D12S300-1 | 4.5~13.8 | 0.6~5 | 60 | 300 | 94 | Through hole | 65.53x31.75x11.0 |
D12S400 | 10.8~13.2 | 0.8375~5 | 80 | 400 | 94 | Through hole | 61.0x31.8x12.3 |
NE12S0A0H03 | 3~13.8 | 0.59~5 | 3 | 15 | 92.5 | DIP | 9.4x15.5x7.9 |
NE12S0A0H06 | 3~13.8 | 0.59~5.1 | 6 | 30.6 | 94.5 | DIP | 10.4x16.5x11.5 |
NE12S0A0H10 | 3~13.8 | 0.59~5.1 | 10 | 51 | 94 | DIP | 10.4x16.5x11.5 |
NE12S0A0V03 | 3~13.8 | 0.59~5 | 3 | 15 | 92.5 | DIP | 9.4x15.5x7.9 |
NE12S0A0V06 | 3~13.8 | 0.59~5.1 | 6 | 30.6 | 94.5 | DIP | 10.4x16.5x11 |
NE12S0A0V10 | 3~13.8 | 0.59~5.1 | 10 | 51 | 94 | DIP | 10.4x16.5x11 |